< Camber


Camber (edgebow or sweep)

Standard Camber Tolerances

Strip
Width

Standard
Camber

Equivalent camber limits: in. (mm)
For various strip lengths: ft. (m)

W
in.
(mm)

tolerance
Ct, in/ft
(mm/m)

 

 

8

4

6

10

12

16

20

 

(2.44)

(1.22)

(1.83)

(3.05)

(3.66)

(4.88)

(6.09)

0.5-1.50

0.50

0.125

0.281

0.781

1.125

2.0

3.125

(12.7-38.1)

(12.7)

(3.18)

(7.14)

(19.84)

(28.58)

(50.8)

(79.38)

1.5-13.0

.25

.0625

0.141

0.391

0.563

1.0

1.562

(38.1-330.2)

(6.35)

(1.59)

(3.58)

(9.93)

(14.30)

(25.4)

(39.68)

If camber is measured over a strip length not shown in table above, it can be easily converted to an equivalent value for comparison with the standard tolerance, using the formula:

Cu = Ck

x (Lu / Lk)2

 

 

where

Cu = Unknown Camber

 

Ck = Known Camber

 

Lu = Unknown Length

 

Lk = Known Length

Standard Camber Tolerances for strip 4 and 8 ft. long
(1.22 m and 2.44 m)
between 0.5 in and 1.5 in (12.7 mm and 38.1 mm) wide
(diagram exaggerated for emphasis)


Back to Contents

> > 26.gif